If you find that your furnace and air conditioner are running concurrently, you could wonder if this is typical or indicative of a problem. Although occasionally it could be a result of system design, usually it points to an underlying problem requiring maintenance by professional like https://www.airconservicing.org/contact/. This article details possible grounds for concern, why your AC and furnace could run simultaneously when it is typical, and how to fix the problem.
Is It Normal For The Furnace And Air Conditioner To Run Simultaneously?
Most conventional HVAC systems call for the AC and furnace not running together. Your house is heated by the furnace; the AC cools it. Running both at once would waste energy since the systems oppose one another. There are, nonetheless, situations when it could be normal:
- Heat Pump Systems: If your heat pump has auxiliary heat, the system may momentarily run both heating and cooling components to keep indoor comfort.
- Dehumidification Mode: During heating cycles, certain contemporary HVAC systems use the air conditioner to eliminate humidity.
Should neither of these scenarios fit, you may be dealing with a problem requiring 7days aircon servicing troubleshooting.
Typical Reasons for Concern:
-
The Thermostat Problems:
The primary point of control in your HVAC system is the thermostat. If it malfunction, it can transmit contradictory signals, running the furnace and AC simultaneously. In smart thermostats, this could result from improper settings, damaged wiring, or software problems.
The system may quickly switch between modes, for example, if the heating and cooling set points of the thermostat are too near. Usually, correct calibration and suitable temperature settings help to fix this problem.
-
Problems with the Control Board:
The HVAC control board coordinates the AC and furnace operations. If something goes wrong with it, it could cause both systems to be turned on simultaneously. Such difficulties might result from wear and tear, power surges, or electrical faults damaging the control board.
If you believe this is the source, it is advisable to have a qualified HVAC specialist check and fix the system as identifying control board problems calls for technical knowledge.
-
Issues with Wiring:
Additionally causing simultaneous operation is improper cabling between the thermostat and the HVAC system. This typically occurs more frequently in systems that are recently repaired or older. Broken or crossed wires could confuse the control system and cause both units to run concurrently. Usually, professional rewiring or exhaustive inspection is needed to resolve these problems and stop more troubles.
Methods of Resolving the Problem:
-
Verify Thermostat Changes:
Examine your thermostat settings first. Make sure the thermostat is set to either heating or cooling—not both—and that the temperature settings are suitable. If your thermostat is programmable, look over the programming schedule for mistakes. Moreover, resetting the thermostat to factory settings helps to fix software problems. Should the issue continue, though, replacing the thermostat might be required.
-
Review The HVAC System:
Sometimes operational problems in the system result from accumulation of dirt and trash in it. Make sure the air filters are clean and that ventilation is unrestricted. Blocked vents could confuse the thermostat and lead one to believe the house need heating and cooling.
-
Plan Professional Maintenance:
If simple troubleshooting fails, you should probably call a qualified HVAC professional. They can carry out the required repairs after doing a thorough investigation, spotting wiring problems, control board faults, or other latent problems.
Conclusion:
Although some HVAC systems are meant to run the AC and furnace concurrently, it is usually a sign of an underlying issue in regular setups. Your HVAC system will work effectively if you know the likely problems and apply the correct remedies. Timely repairs, correct settings, and regular maintenance will keep your house comfortable and help you to save energy.